show auto_path_change
Description Shows whether implicit (automatic) path changing enabled and lists the
criteria that must be met for an automatic LUN ownership change.
Syntax
show auto_pa
th_change
Operands None
Example
CLI> show auto_path_change
Implicit (automatic load-based) LUN ownership changes are currently ENABLED.
Implicit LUN ownership change preferences are as follows:
Minimum % of proxied requests to trigger implicit path change..: 75%
Minimum number of requests to LUN before path change enabled...: 128
Minimum time to wait before changing ownership after power-up..: 30 minutes
Minimum time between ownership changes for LUN.................: 30 minutes
See also set auto_pa
th_change
show preferred_path