HP Moonshot-45G Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Software HP Moonshot-45G herunter. HP Moonshot-45G User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 76
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
HP Moonshot iLO Chassis Management
Web Interface
User Guide
Abstract
This guide provides information about configuring, updating, and operating HP Moonshot Systems by using the Moonshot iLO
Chassis Management web interface. This document is intended for system administrators, HP representatives, and HP Authorized
Channel Partners who are involved in configuring and using HP Moonshot Systems.
HP Part Number: 798886-001
Published: November 2014
Edition: 1
Seitenansicht 0
1 2 3 4 5 6 ... 75 76

Inhaltsverzeichnis

Seite 1 - Web Interface

HP Moonshot iLO Chassis ManagementWeb InterfaceUser GuideAbstractThis guide provides information about configuring, updating, and operating HP Moonsho

Seite 2

Setting up Moonshot by using the Moonshot iLO CM firmware web interfaceYou can use the iLO CM firmware web interface to configure the Moonshot System

Seite 3 - Contents

3 Using the web interface to view Moonshot System detailsThis chapter provides information about viewing the available information using Moonshot webi

Seite 4 - 4 Contents

Viewing overview informationViewing Moonshot general informationFrom the main menu, select Chassis to display high level information about the chassis

Seite 5 - Moonshot web interface

◦ Critical—Service lost or imminent service loss, immediate attention needed◦ Unknown• Cartridge numberNOTE: Click the cartridge number link to open t

Seite 6

• UID control—click this icon to turn the switch UID on or off.UID is off. Click the icon to turn the UID on.◦◦ UID is on. Click the icon to turn the

Seite 7

The Cartridge Health gauge shows the health of all cartridges. The gauge is divided into cartridgesthat have critical issues, issues that cause degrad

Seite 8

Selecting multiple cartridgesTo select multiple cartridges from the cartridge list, do one of the following:• Hold Ctrl and click each cartridge to be

Seite 9 - • Moonshot-6SFP Uplink Module

The System Firmware section displays the version information for the following firmware installedon the selected cartridge:• System ROM firmware• CPLD

Seite 10

From the main menu, select Cartridges to view the Cartridges page. The page defaults to anoverview of the first cartridge in the list of all available

Seite 11 - Browser support

• Select a preset range or a date range in the Created on menu.• To search for events based on dates, event IDs, or description text, enter text in th

Seite 12 - Viewing overview information

© Copyright 2012, 2014 Hewlett-Packard Development Company, L.PConfidential computer software. Valid license from HP required for possession, use or c

Seite 13

1. Click Actions→View CSV.The Moonshot Event Log CSV for the cartridge is displayed.2. Click Save or click Close to close the window.Clearing the cart

Seite 14 - Viewing the chassis back view

The Thermal table displays the following information for the selected cartridge:• Sensor—The ID of the temperature sensor, which also gives an indicat

Seite 15

Customizing the node listYou can customize which nodes are displayed in the node list by using the node filter menus. Aselected filter is bold. Click

Seite 16

The Node status section displays the following:• Power—The node power status.◦ The node is off.◦ The node is on.The Node Details section displays the

Seite 17 - Viewing cartridge logs

1. Click Actions→Boot options. The Select boot options page displays.2. In the Select boot order section, select the following:• Boot device 1—The pri

Seite 18

Changing the power state of a nodeTo change the power state of a node:1. Select one or more nodes.2. The available selections depend on the current st

Seite 19

Customizing the node log viewYou can customize which log entries are displayed as follows:• To filter by severity, select a severity level from the Se

Seite 20

Saving a node event logTo save the node event log as a CSV file:1. Select Actions→View CSV.The node event log is displayed in a format that you can co

Seite 21

• Product ID—The product ID of the switch. This value is set by the manufacturer, but can bechanged by an Administrator using the iLO CM firmware comm

Seite 22 - Customizing the node list

Changing the state of a switch’s UID1. Select the check box next to either Switch A or Switch B. You cannot select both switches atonce.2. The availab

Seite 23 - ◦ The node is on

Contents1 Introduction to the HP Moonshot iLO Chassis Management web interface...5Overview...

Seite 24

Customizing the switch log viewYou can customize which log entries are displayed as follows:• To filter by severity, select a severity level from the

Seite 25 - Viewing node logs

3. Click Save or click Close to close the window.Clearing a switch logUsers with the Administrator privilege can clear switch logs of all previously l

Seite 26

The Thermal table displays the following information for each switch:• Sensor—The ID of the temperature sensor, which also gives an indication of the

Seite 27

• Satellite—The satellite firmware version.• Data—The switch data file version.CartridgesThis section displays the following information about the ins

Seite 28 - ◦ The UID is on

The Power Supplies section displays the following:• Bay—The bay number of the power supply.• Status—The status of the power supply.• Model—The model n

Seite 29 - Viewing switch logs

◦ Critical—Service lost or imminent service loss, immediate attention needed◦ Disabled or Not installed—Service is unavailable or the component is not

Seite 30

The Temperatures page displays the following information:• Sensor—The ID of the temperature sensor, which also gives an indication of the sensor locat

Seite 31

The following information is listed for each session:• User—The login name used to log in to the session.• IP—The IP address of the computer used to l

Seite 32 - Viewing firmware information

4. Click Yes to continue, or click Cancel.If you disconnected the current session, the browser returns to the login page.If you disconnected a remote

Seite 33 - Power Supplies

4 Configuring Moonshot SystemThis chapter includes procedures for configuring a Moonshot System by using the iLO CM firmwareweb interface.Updating fir

Seite 34 - Viewing fan information

Saving the event log...61Clearing the event lo

Seite 35

HP Moonshot Component Pack is a comprehensive firmware solution tested on the HP MoonshotSystem and delivered as a compressed file. The compressed fil

Seite 36

such as c6–10, or multiple specific cartridges, such as c6,8,10. Enter all to uploada firmware file to all cartridges.• Switches—Specify the switch. T

Seite 37

Viewing local user accountsTo view local user accounts, select User Administration from the main menu.The User Administration page shows the login nam

Seite 38 - Viewing the time settings

3. Provide the following details:• Full name appears in the user list on the User Administration page. It does not have tobe the same as the Login nam

Seite 39 - 4 Configuring Moonshot System

Password guidelinesHP recommends that you follow these password guidelines:• The maximum password length is 39 characters.• Passwords can include any

Seite 40 - Uploading firmware

3. Enter the following information in the Information section:• Country (C)—The two-character country code that identifies the country where the compa

Seite 41

5. After a few minutes (up to 10), click Generate CSR again, or select Actions→View CSR on theSSL Certificate page.The CSR is displayed.The CSR contai

Seite 42 - Viewing local user accounts

5. Select Browse local files or Copy into text box. This determines the method of inserting thecertificate contents into the iLO CM firmware.• Browse

Seite 43

3. Click Save to save the CSR text to a file.For information about using the CSR to obtain a trusted certificate, see “Obtaining a trustedSSL certific

Seite 44 - Configuring security

The General section lists the following:• MAC address—The MAC address of the iLO CM management port on the Moonshot 1500CM module.• Host name—The Moon

Seite 45 - Configuring security 45

1 Introduction to the HP Moonshot iLO Chassis Managementweb interfaceOverviewThe Moonshot iLO Chassis Management web interface allows GUI-based aggreg

Seite 46

1. From the main menu, select Network Configuration.The IPv4 summary section displays the DHCPv4 status, IPv4 address, Subnet mask, and Defaultgateway

Seite 47 - Configuring security 47

2. Select IPv4 in the View menu in the upper left corner of the page, or click the More link in theIPv4 summary section.The following information is d

Seite 48 - Managing network settings

Configuring IPv4 settings1. Select Network Configuration from the main menu.2. Select Actions→Edit.3. Configure the following settings in the IPv4 sec

Seite 49 - Viewing IPv4 information

5. Configure the following settings in the Advanced section:• Ping gateway on startup—Causes the iLO CM Firmware to send four ICMP echo requestpackets

Seite 50

◦ WINS—Specifies whether the DHCP server-supplied WINS server list is used. If not,enter the WINS server addresses in the Primary WINS server and Seco

Seite 51 - Managing network settings 51

Configuring the host nameWhen you configure the Moonshot 1500 CM module host name, note the following limitations:• Name service limitations—The host

Seite 52 - Configuring IPv4 settings

5. Click Yes.A reset ends all active sessions. It might take several minutes before you can re-establish aconnection.Configuring SNTP settingsViewing

Seite 53 - Managing network settings 53

3. Do one of the following:• Select the Configure using DHCPv4 check box to use a DHCP-provided NTP server address.NOTE: To configure a DHCPv4-provide

Seite 54

6. Click Apply to save the changes.The following message appears:The chassis manager will automatically reset to apply the settings.Continue to apply

Seite 55 - Managing network settings 55

5 Working with eventsUsing the iLO CM event logThe event log provides a record of significant events recorded by the iLO CM firmware.Logged events inc

Seite 56 - Configuring SNTP settings

1. HP Moonshot main menu: The primary menu for navigating to resources. Click to expand.2. View customization menus: Filters your view to only the des

Seite 57 - Managing network settings 57

• Last Update—The date and time when the latest event of this type occurred. This value is basedon the date and time stored by the iLO CM firmware.For

Seite 58

• To filter by the Initial Update date, select a date range in the Initial Update menu.• To search for events based on dates, event IDs, or descriptio

Seite 59 - 5 Working with events

3. Click Save, and then follow the browser prompts to save or open the file.4. Click Close to close the window.Clearing the event logUsers with the Ad

Seite 60 - 60 Working with events

• Switch insertion and removal• IML clearedViewing the IMLTo view the IML, select Integrated Management Log in the main menu.The IML displays the foll

Seite 61 - Saving the event log

• Initial Update—The date and time when the first event of this type occurred. This value is basedon the date and time stored by the iLO CM firmware.•

Seite 62 - Using the iLO CM IML

• To filter by the Initial Update date, select a date range in the Initial Update menu.• To search for events based on dates, event IDs, or descriptio

Seite 63 - Using the iLO CM IML 63

3. Select the log entry.To select an IML entry, click the check box next to the entry in the first column of the IML table.If a check box is not displ

Seite 64 - Customizing the IML view

2. Select Actions→View CSV.The IML is displayed.3. Click Save, and then follow the browser prompts to save or open the file.4. Click Close to close th

Seite 65 - Using the iLO CM IML 65

6 TroubleshootingThis chapter provides troubleshooting solutions for the Moonshot Web Interface.Bypassing a lost or forgotten administrator passwordHP

Seite 66 - Saving the IML

4. Reinsert the Moonshot 1500 CM module and wait for it to boot.5. Connect to the Moonshot iLO CM firmware using a serial port or SSH. When the Login

Seite 67 - Clearing the IML

For more information about the HP RESTful API see the following website: http://www.hp.com/go/restfulinterface/docs.HP RESTful API for Moonshot iLO Ch

Seite 68 - 6 Troubleshooting

9. Insert the Moonshot 1500 CM module.10. Verify access to the Moonshot iLO CM firmware with the new username or password.70 Troubleshooting

Seite 69

7 Support and other resourcesInformation to collect before contacting HPBe sure to have the following information available before you contact HP:• So

Seite 70 - 70 Troubleshooting

• HP Moonshot-45G Switch Administrator's Guide• HP Moonshot Component Pack Release Notes• HP Insight Cluster Management Utility v7.1 User Guide•

Seite 71 - 7 Support and other resources

NOTE: Provides additional information.TIP: Provides helpful hints and shortcuts.Typographic conventions 73

Seite 72 - Typographic conventions

8 Documentation feedbackHP is committed to providing documentation that meets your needs. To help us improve thedocumentation, send any errors, sugges

Seite 73 - Typographic conventions 73

IndexAactive iLO sessionsdisconnecting, 37active sessionsviewing, 36authorized resellers, 71Bbrowser supportweb interface, 11Ccertificate signing requ

Seite 74 - 8 Documentation feedback

network connection, 8overview, 8setting up Moonshotweb interface, 10SSLviewing certificates, 44SSL certificatesimporting, 46obtaining, 44static routes

Seite 75

2 Setting up a Moonshot SystemOverviewThe default settings enable you to use most features without additional configuration. However,the configuration

Seite 76 - 76 Index

Data center production networkTo connect the chassis to a production network, connect to any available SFP+ or QSFP+ port.The SFP+/QSFP+ ports are loc

Kommentare zu diesen Handbüchern

Keine Kommentare