HP 625590-001 Datenblatt

Stöbern Sie online oder laden Sie Datenblatt nach Server HP 625590-001 herunter. HP ProLiant 370 G6 Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 62
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
The next generation of the HP ProLiant ML370 (expandable tower chassis) and the new HP ProLiant DL370 (4U rack optimized
chassis) deliver Industry-leading management tools, leading performance, expandability, flexibility and the latest energy efficient
technologies. These servers are well-suited for deployment in growing businesses, remote office sites, or datacenters and have been
designed to bring you (our customer) the utmost confidence to run your business.
HP ProLiant DL370 G6 (Rack)
HP ProLiant DL370 G6 (Rack)HP ProLiant DL370 G6 (Rack)
HP ProLiant DL370 G6 (Rack)
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
Quick removal access panel
1.
Mouse connector
2.
Three Hot-plug fans (standard) Five (optional)
2.
Keyboard connector
3.
Intel Six or Quad-Core Processor (Performance model
includes two processors)
3.
Serial connector
4.
iLO 2 connector
4.
Eighteen slots for DDR3 Registered or Unbuffered Memory
5.
Two USB connectors
5.
SAS/SATA drive cage
6.
9 Available PCI-Express Gen2 expansion slots; PCI-X
(optional)
6.
Optional drive cage bay
7.
PCI-X Expansion slot riser bay
7.
Power on/standby button, video connector and two USB
connectors
8.
Four NIC connectors
8.
System Insight Display
9.
Video connector
9.
Removal media bay
10.
Power supply bay 2
10.
DVD-ROM drive
11.
Power supply bay 1 (populated)
11.
Optional slimline optical drive bay
12.
9 Available PCI-Express Gen2 slots; PCI-X (optional)
QuickSpecs
HP ProLiant DL370 Generation 6 (G6)
HP ProLiant DL370 Generation 6 (G6)HP ProLiant DL370 Generation 6 (G6)
HP ProLiant DL370 Generation 6 (G6)
HP ProLiant ML370 Generation 6 (G6)
HP ProLiant ML370 Generation 6 (G6)HP ProLiant ML370 Generation 6 (G6)
HP ProLiant ML370 Generation 6 (G6)
Overview
DA - 13242 North America — Version 48 — January 13, 2012
Page 1
Seitenansicht 0
1 2 3 4 5 6 ... 61 62

Inhaltsverzeichnis

Seite 1 - QuickSpecs

The next generation of the HP ProLiant ML370 (expandable tower chassis) and the new HP ProLiant DL370 (4U rack optimizedchassis) deliver Industry-lead

Seite 2

WarrantyWarrantyWarrantyWarrantyThis product is covered by a global limited warranty and supported by HP Services and a worldwidenetwork of HP Authori

Seite 3

HP Insight managementHP Insight managementHP Insight managementHP Insight managementsoftwaresoftwaresoftwaresoftwareHP Insight ControlHP Insight Contr

Seite 4

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster PlatformsHP Cluster PlatformsHP Cluster Pla

Seite 5

Service and SupportService and SupportService and SupportService and SupportHP Technology Services for Industry Standard Servers and BladeSystemHP Tec

Seite 6

Standard CareStandard CareStandard CareStandard CareStandard Care Package: Package that maintains high level of server availabilityStandard Care Packa

Seite 7

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Seite 8

FansFansFansFans(5) Fully Redundant Hot Plug FansForm FactorForm FactorForm FactorForm Factor4U RackWarrantyWarrantyWarrantyWarrantyServer Warranty in

Seite 9

The ProLiant Smart Buy program offers a collection of promotional server and option products that are configured with SMB in mind,offered at discounte

Seite 10

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Seite 11

HP Smart Array P410i/Zero Memory Controller(6) Hot-Plug (LFF) SAS/SATA Drive Bays(9) available PCI-e Gen2 slots(5) USB ports(3) Hot Plug Fans4U Rack F

Seite 12

HP ProLiant ML370 G6 (Tower)HP ProLiant ML370 G6 (Tower)HP ProLiant ML370 G6 (Tower)HP ProLiant ML370 G6 (Tower)Front View:Front View:Front View:Front

Seite 13

HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9Memory Kit593339-B21HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registere

Seite 14

Step 3: Choose Additional Factory Integratable OptionsStep 3: Choose Additional Factory Integratable OptionsStep 3: Choose Additional Factory Integrat

Seite 15

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Seite 16

HP ML/DL370 G6 Intel® Xeon® W5580 (3.20GHz/4-core/8MB/130W) ProcessorKit495928-B21HP ML/DL370 G6 Intel® Xeon® X5570 (2.93GHz/4-core/8MB/95W) Processor

Seite 17

HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 LowPower Memory KitNOTE:NOTE:NOTE:NOTE: Low Voltage DIMMs can only be used with In

Seite 18

NOTE:NOTE:NOTE:NOTE: Hard drives have either a one year or three year warranty; refer to the specifichard drive QuickSpecs for details.SAS Hot Plug SF

Seite 19

NOTE:NOTE:NOTE:NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/quickspecs/12

Seite 20

HP 200GB 6G SAS SLC SFF (2.5-inch) Enterprise Performance 3yr Warranty SolidState Drive632492-B216G SAS Hot Plug Enterprise Mainstream Solid State Dri

Seite 21

HP InfiniBandHP InfiniBandHP InfiniBandHP InfiniBandHP InfiniBand 4X DDR PCI-E 0 Memory Dual Port HCA483513-B21QLogic InfiniBand 4X QDR PCI-E G2 Dual

Seite 22

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Seite 23

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Seite 24

http://h18000.www1.hp.com/products/quickspecs/13019_na/13019_na.htmlHP Integrated Lights-Out (iLO) AdvancedHP Integrated Lights-Out (iLO) AdvancedHP I

Seite 25

HP High Performance Computing Linux Value Pack 1 Processor Flexible LicenseNOTE:NOTE:NOTE:NOTE: This part number can be used to purchase one certifica

Seite 26

HP Security - TPMHP Security - TPMHP Security - TPMHP Security - TPMHP Trusted Platform Module Option488069-B21NOTE:NOTE:NOTE:NOTE: The TPM (Trusted P

Seite 27

Single Server LicenseNOTE:NOTE:NOTE:NOTE: This part number can be used to purchase a single license or to order multiplelicenses with a single activat

Seite 28

HP Backup & RecoveryHP Backup & RecoveryHP Backup & RecoveryHP Backup & RecoverySoftwareSoftwareSoftwareSoftwareHP Data Protector Expr

Seite 29

HP MSL2024 1 LTO-5 Ultrium 3000 SAS Tape LibraryNOTE:NOTE:NOTE:NOTE: Connection using HP P212 SAS Smart Array Controller (462828-B21)recommended.BL537

Seite 30

HP Storage OptionsHP Storage OptionsHP Storage OptionsHP Storage OptionsFibre Channel HBAFibre Channel HBAFibre Channel HBAFibre Channel HBANOTE:NOTE:

Seite 31

HP Uninterruptible PowerHP Uninterruptible PowerHP Uninterruptible PowerHP Uninterruptible PowerSystemsSystemsSystemsSystemsHP Tower UPSHP Tower UPSHP

Seite 32

HP Rack SeriesHP Rack SeriesHP Rack SeriesHP Rack SeriesHP Rack 10000 G2 SeriesHP Rack 10000 G2 SeriesHP Rack 10000 G2 SeriesHP Rack 10000 G2 Series (

Seite 33

HP Server Console Switch G2 with Virtual Media & CACHP Server Console Switch G2 with Virtual Media & CACHP Server Console Switch G2 with Virtu

Seite 34

depend on the quantity and type of DIMMs installed.NOTE:NOTE:NOTE:NOTE: For the Intel 5600 and 5500 Series, the letter preceding the model number indi

Seite 35

Smart Buy Care PackSmart Buy Care PackSmart Buy Care PackSmart Buy Care PackServicesServicesServicesServicesHP ProLiant ML370 G6 Service & Support

Seite 36

NOTE:NOTE:NOTE:NOTE: Memory configurations listed do not apply to "Factory Integrated Models".HP ProLiant DL370 G6 ModelsHP ProLiant DL370 G

Seite 37

POPULATED DIMM SPEED (MHz)POPULATED DIMM SPEED (MHz)POPULATED DIMM SPEED (MHz)POPULATED DIMM SPEED (MHz)1 DIMM Per Channel1333 1333 1333 1066 1333 13

Seite 38

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; empty2D; empty3A; 2GB DIMM3A; empty

Seite 39

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; 8GB DIMM1G; emptyChnl 12D; 8GB DIMM2D; empty3A; 8GB DIMM3A;

Seite 40

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 32GB DIMM2D; 32GB DIMM3A; 32GB DIMM

Seite 41

Following are memory options available from HP:Following are memory options available from HP:Following are memory options available from HP:Follo

Seite 42

HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9Memory Kit500672-B21HP 4GB (1x4GB) Dual Rank x8 PC3L-10600 (DDR3-1333) Unbuffered CA

Seite 43

ARemovable media bayBSATA DVD-ROM Drive (Standard in all BTO Models)COptical Drive (blank)1-8Eight SFF SAS/SATA HDD Bays (Standard in all BTOModels)AR

Seite 44

1-14Fourteen large form factor (LFF) hot-plug drive bays tosupport Serial-attached SCSI (SAS) and Serial ATA(SATA) drives with optional drive cages Dr

Seite 45

Expansion SlotsExpansion SlotsExpansion SlotsExpansion SlotsNOTE:NOTE:NOTE:NOTE: Nine (9) available PCI-Express Gen2 expansion slots to provide you wi

Seite 46

HP Smart Array P411/1G FBWC ControllerHP Smart Array P812/1G FBWC ControllerSAS Hot Plug LFF (3.5-inch) Enterprise (ENT) DrivesSAS Hot Plug LFF (3.5-i

Seite 47

HP Smart Array P411/512 MB FBWC ControllerHP Smart Array P411/1G FBWC ControllerHP Smart Array P812/1G FBWC ControllerSATA Hot Plug SFF (2.5-inch) Mid

Seite 48

HP Smart Array P411/512 MB BBWC ControllerHP Smart Array P411/512 MB FBWC ControllerHP Smart Array P411/1G FBWC ControllerHP Smart Array P812/1G FBWC

Seite 49

HP Smart Array P411/1G FBWC ControllerHP Smart Array P812/1G FBWC Controller6G SAS Hot Plug Enterprise Mainstream Solid State Drives6G SAS Hot Plug En

Seite 50

Tape and Disk BackupTape and Disk BackupTape and Disk BackupTape and Disk BackupNOTE:NOTE:NOTE:NOTE: For the complete range of tape drives, autoloader

Seite 51

HP SCSI Tape LibrariesHP SCSI Tape LibrariesHP SCSI Tape LibrariesHP SCSI Tape LibrariesMSL2024MSL4048MSL8096MSL6000ExternalHP U320e SCSI Dual Channel

Seite 52

HP 460W Common Slot Gold Hot Plug Power Supply KitHP 460W Common Slot Gold Hot Plug Power Supply KitHP 460W Common Slot Gold Hot Plug Power Supply Kit

Seite 53

HP 1200W Common Slot Silver Hot Plug Power Supply KitHP 1200W Common Slot Silver Hot Plug Power Supply KitHP 1200W Common Slot Silver Hot Plug Power S

Seite 54

System UnitSystem UnitSystem UnitSystem UnitTower DimensionsTower DimensionsTower DimensionsTower Dimensions(H x W x D) (with bezel)18.52 x 9.75 x 29.

Seite 55

System Inlet TemperatureSystem Inlet TemperatureSystem Inlet TemperatureSystem Inlet TemperatureOperating10° to 35°C (50° to 95°F) at sea level with a

Seite 56

Storage ControllerStorage ControllerStorage ControllerStorage ControllerOne of the followingdepending on ModelEntry ModelsHP Smart Array P410i/256 MB

Seite 57

NOTE:NOTE:NOTE:NOTE: Product conformance to cited product specifications is based onsample (type) testing, evaluation, or assessment. This product or

Seite 58

NC375i Integrated QuadNC375i Integrated QuadNC375i Integrated QuadNC375i Integrated QuadPort Gigabit ServerPort Gigabit ServerPort Gigabit ServerPort

Seite 59

SecuritySecuritySecuritySecurityAdvanced Encryption Standard (AES) and Triple Data Encryption Standard(3DES) on browser, CLP and XML scripting interfa

Seite 60

Industry StandardIndustry StandardIndustry StandardIndustry StandardComplianceComplianceComplianceComplianceACPI V2.0 CompliantPCI-Express Gen2PXE Sup

Seite 61

Operating Systems andOperating Systems andOperating Systems andOperating Systems andVirtualization SoftwareVirtualization SoftwareVirtualization Softw

Seite 62

HP Insight SoftwareHP Insight SoftwareHP Insight SoftwareHP Insight SoftwareHP Insight FoundationManaging the growing number of servers can be complex

Kommentare zu diesen Handbüchern

Keine Kommentare