HP 487503-421 Datenblatt

Stöbern Sie online oder laden Sie Datenblatt nach Server HP 487503-421 herunter. HP ProLiant 180 G6 Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 57
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellence
and 2U density for a variety of rack deployments and applications.
Front View:
Rear View:
1.
Access panel
1.
Redundant Power Supply Bay (Optional)
2.
Front LED Indicators
2.
Power Supply Cable Socket
3.
Power on/off
3.
Low Profile Card Slot
4.
Optional DVD-RW or DVD-ROM drive
4.
PCI Expansion Card Slot
5.
Front USB Ports (2)
5.
PCI Expansion Card Slot
6.
Non-Hot Plug Non Redundant fans (4 fans)
6.
UID LED Button
7.
Air Baffle
7.
(Optional) LO100i 10/100 Mbps LAN port for IPMI
management (RJ-45)
8.
PCI Cage
9.
System Board
8.
LAN Port
9.
LAN Port
10.
2 Rear USB 2.0 Ports
11.
VGA Port
12.
Serial Port
What's New
Support for HP 3TB 3G SATA 7.2K 3.5in MidlLine Hard Drive
QuickSpecs
HP ProLiant DL180 Generation 6 (G6)
Overview
DA - 13248 Worldwide — Version 53 — September 24, 2012
Page 1
Seitenansicht 0
1 2 3 4 5 6 ... 56 57

Inhaltsverzeichnis

Seite 1 - QuickSpecs

The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellenceand 2U density for

Seite 2

HP Insight Controlmanagement softwareHP Insight Control forLinuxHP Insight Control for Linux, as a product option, delivers essentialinfrastructure ma

Seite 3

High PerformanceClustersHP Cluster PlatformsHP Cluster Platforms are specifically engineered, factory-integrated large-scale ProLiant clusters optimiz

Seite 4

Service and SupportHP Technology Services for Industry Standard Servers and BladeSystemCapitalizing on HP ProLiant server and HP BladeSystem capabilit

Seite 5

Standard Care PackagePackage that maintains high level of server availabilityHP ProLiant Server Hardware InstallationProvides for the basic hardware i

Seite 6

Four Drive Serial ATA (SATA) ModelsNOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configur

Seite 7

Eight Drive Serial ATA (SATA) ModelsNOTE: Supports up to 8 Hot Plug SATA or SAS Hard Drives.HP ProLiant DL180 G6E5620 1P 8GB-R P410/256BBWC 8 LFF 460W

Seite 8

Twelve Drive Serial ATA (SATA) ModelsNOTE: Internal Storage expandable to 14 SAS/SATA drives with 2 Rear Drive Option Kit (P/N 488234-B21)HP ProLiant

Seite 9

HP ProLiant DL180 G6X5650 2P 16GB-RP410/256 BBWC 25 SFF750W PS Server590640-xx1Processor(2) Intel® Xeon® X5650 (2.66GHz/6-core/12MB/95W, DDR3-1333, HT

Seite 10

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areordered, HP recomm

Seite 11

Step 2: Choose Required Options (only one of the following from each list unless otherwisenoted)HP ProcessorsNOTE: If 2 processors are desired, select

Seite 12

NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - FactoryIntegrated Models&qu

Seite 13

HP Drive Cage OptionsHP 2U G6 4HDD CAGE Kit, FIO506926-B21HP 2U G6 8HDD CAGE Kit, FIO506927-B21HP 2U G6 12HDD CAGE Kit, FIO506928-B21HP 2U 8SFF HDD CA

Seite 14

NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use ofan HP approved confi

Seite 15

HP DL180 G6 Intel® Xeon® E5520 (2.26GHz/4-core/8MB/80W) Processor Kit508342-B21NOTE: HT indicates that the processor model supports Intel® Hyper-Threa

Seite 16

HP Hard DrivesNOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, andthe server backplane) should operate at the same dat

Seite 17

HP 146GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive512547-B21SAS Hot Plug LFF (3.5-inch) Enterprise (ENT) DrivesNOTE:

Seite 18

SATA Hot Plug LFF (3.5-inch) Entry (ETY) DrivesHP 250GB 3G SATA 7.2K rpm LFF (3.5-inch) Entry 1yr Warranty Hard Drive571230-B21NOTE: Please see the Qu

Seite 19

NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation: www.hp.com/go/ProLiantNICs. HP InfiniBandQLogic InfiniBand 4X

Seite 20

NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use ofan HP approved confi

Seite 21

NOTE: Licenses ship without media. The Insight Control Media Kit can be orderedseparately, or can be downloaded at: http://www.hp.com/go/insightupdate

Seite 22

HP I/O AcceleratorOptionsSecond Generation Accelerators HP 365GB Multi Level Cell G2 PCIe ioDrive2 for ProLiant Servers673642-B21HP 785GB Multi Level

Seite 23

Memory ProtectionAdvanced memory protectionMirroring ModeLockstep ModeMemoryTypeDDR3 Registered (RDIMM) or Unbuffered (UDIMM)DIMM slotsTotal 12 DIMM s

Seite 24

HP Smart Array P410/256 2-ports Int PCIe x8 SAS Controller462862-B21HP Smart Array P410/512 BBWC 2-ports Int PCIe x8 SAS Controller462864-B21HP Smart

Seite 25

NOTE: Please see the following QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/quickspecs/13203_d

Seite 26

HP Ultrium 920 SAS Internal Tape DriveNOTE: For installation into 1U SAS Rack-Mount Kit (AE459B) or 3U SAS Rack-Mount Kit(AG576B). No peripheral bay a

Seite 27

HP Storage OptionsFibre Channel HBANOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows andLinux. For detailed compatibili

Seite 28

HP R5KVA 3U IEC309-32A High Voltage INTL Uninterruptible Power SystemAF461AHP R5KVA 3U L630 High Voltage NA/JP Uninterruptible Power SystemAF460ANOTE:

Seite 29

HP Power DistributionUnitsMonitored PDUsHP Monitored Power Distribution Unit: Full Rack Version HP 8.6kVA 24A Single Input Three Phase NA/JP Monitored

Seite 30

HP Intelligent PowerDistribution Units (iPDU)iPDU Core UnitsHP 4.9kVA 24A Single Phase NA/JP Core Intelligent Modular Power Distribution UnitAF520AHP

Seite 31

HP 1x1Ex8 KVM IP Console Switch G2 with Virtual Media CAC SoftwareAF620AHP 2x1Ex16 KVM IP Console Switch G2 with Virtual Media CAC SoftwareAF621AHP 4x

Seite 32

NOTE: Memory configurations listed do not apply to "Factory Integrated Models".HP ProLiant DL180 G6Standard Memory (depending on model)4GB (

Seite 33

DIMM Type ->Registered DIMMS (RDIMMs)Unbuffered with ECC DIMMs(UDIMMs)DIMM Rank ->SingleRank(1R)Dual Rank (2R)Quad Rank (4R)SingleRank(1R)Dual R

Seite 34

Storage ControllerOne of the followingdepending on Model4HDD ModelsHP Smart Array B110i SATA RAIDNOTE: To enable RAID on Embedded SATA, use the HP Sma

Seite 35

12 DIMM SLOTS (6 per CPU node) CPU1 CPU2 slot #population orderslot #population order Chnl 11D1DChnl 12A2A Chnl 23E3EChnl 24B4B C

Seite 36

Standard memory replaced with optional memory (1 CPU model)RDIMM maximum configuration96GB, consisting of six (6) 16GB quad-rank PC3-8500 RDIMMs CPU1

Seite 37

UDIMM maximum configuration (2 CPU model)48GB, consisting of twelve (12) 4GB dual-rank PC3-10600 UDIMMs CPU1 CPU2 slot #population orderslot #populat

Seite 38

HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low PowerMemory Kit604504-B21HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333)

Seite 39

8 Drive Cage with DVD-Drive bay 1-8Eight 3.5" Hot Plug SAS/SATA Hard Drive Bays9DVD-ROM, DVD RW12 Drive Cage 1-12Twelve 3.5" Hot Plug SA

Seite 40

HP Smart Array P410/512 MB FBWC ControllerHP Smart Array P410/1G FBWC ControllerHP Smart Array P812/1G FBWC ControllerHP Smart Array P800/512 BBWC Con

Seite 41

SSD200GB 3G SATA MLC SFFSSD100GB 3G SATA MLC SFFSSDdrive cageHP Smart Array P212/256 MB ControllerHP Smart Array P410/256 MB ControllerHP Smart Array

Seite 42

HP Smart Array P410/512 MB BBWC ControllerHP Smart Array P410/512 MB FBWC ControllerHP Smart Array P410/1G FBWC ControllerHP Smart Array P812/1G FBWC

Seite 43

QuantitySupportedPositionSupportedController400GB 6G SAS SLC 200GB6G SAS SLCUp to 41-4HP Smart Array P212 ControllerHP Smart Array P410 ControllerHP

Seite 44

DAT 160DAT 3201U USB Rack-Mount Kit HP SAS Tape DrivesDAT 160DAT 320LTO-2 Ultrium 448LTO-3 Ultrium 920LTO-4 Ultrium 1760LTO-4 Ultrium 1840LTO-5 Ultr

Seite 45

Maximum InternalStorageOne of the followingdepending on ModelHot Plug 3.5" SATA42.0TB (14 x 3TB)Hot Plug 3.5" SAS42.0TB (14 x 3TB)Hot Plug 2

Seite 46

HP D2D Backup Systems,iSCSID2D2500iD2D4000iExternalEmbedded Network Controller. If the server requires a hardwareiSCSI initiator, the QLogic QLA4050 H

Seite 47

HP 460W Common Slot Gold Hot Plug Power Supply KitPart Number503296-B21Input Voltage Range (Vrms)100 to 240Frequency Range (Nominal) (Hz)50/60Nominal

Seite 48

HP 460W Common Slot Platinum Hot Plug Power Supply KitPart Number593188-B21Input Voltage Range (Vrms)100 to 240Frequency Range (Nominal) (Hz)50/60Nomi

Seite 49

HP 1200W Common Slot -48VDC Hot Plug Power Supply KitPart Number437573-B21Input Voltage Range (Vrms)36-72Frequency Range (Nominal) (Hz)DCNominal Input

Seite 50

System UnitDimensions (H x W x D)(with bezel)3.45" x 17.64" x 28.23" in (8.76 x 44.80 x 71.71 cm)Weight(approximate)Maximum(all hard dr

Seite 51

System performance may be reduced if operatingwith a fan fault or above 30°C (86°F).Non-operating-30° to 60°C (-22° to 140°F). Maximum rate ofchange i

Seite 52

Smart Array P212ControllerDisk Drive and EnclosureInterface3G SAS (Serial Attached SCSI)1.5G SATA (Serial ATA)SAS Connectors1 internal/1 external (Min

Seite 53

Environment-friendlyProducts and ApproachEnd-of-life Managementand RecyclingHewlett-Packard offers end-of-life HP product return, trade-in, and recycl

Seite 54

Common Slot PowerSupplyHP has a new design for ProLiant power. The new Common Slot Power Supply bay. This design providesthe customer with commonality

Seite 55

Form FactorRack (2U), (3.5 in/8.89 cm)Embedded ManageabilityHP Lights-Out 100(LO100) AdvancedHP LO100 with Optional LO100 Advanced Licenses for Virtua

Seite 56

greater to manage ProLiant 100-series G6 servers. Administrators canalso use any other SNMP- based management tool. These agents areobtained as part o

Seite 57

Subscriber's ChoiceSubscriber's Choice Driver and Support Alerts/Notifications is a web-basedemail subscription service that provides softwa

Kommentare zu diesen Handbüchern

Keine Kommentare