5 Connect the power cables
Requirements
An electrician is required for the setup and configuration and building of the electrical system used to
power the printer and also for printer installation. Make sure that your electrician is appropriately certified
according to local regulations and supplied with all the information regarding the electrical configuration.
Configure the building's electrical system used to power the printer to meet the printer's requirements
and the Electrical Code requirements of the local jurisdiction of the country where the equipment is
installed. A qualified electrician is required.
Your printer requires the following electrical components to be supplied and installed by the customer,
according to the Electrical Code requirements of the local jurisdiction of the country where the equipment
is installed.
Remember that you are required to follow the local laws, regulations, and standards that pertain to the
electrical installation of your printer.
Tri-phase AC Power Cord
The cable must meet the requirements of the printer and should be in accordance with the Electrical
Code requirements of the local jurisdiction of the country where the equipment is installed.
Printer's tri-phase line specifications High-voltage systems Low-voltage systems
Input voltage (line to line) 3 x 380–414 V~ (-10% +6%) 3 x 200–220 V~ (±10%)
Input frequency 50 Hz 60 Hz (1)
Power Consumption 15 KW 15 KW
Maximum Load Current 30 A 50 A
1
Japan may have input frequencies of 50 Hz or 60 Hz
Power Cord Specification
High-voltage systems High-voltage systems
Configuration 4 Wires, L1/L2/L3/PE
Minimum cross-sectional area
AWG6, 16mm
2
AWG6
The power cord must enter into the printer through the AC power gland, and securely fit into it, in order
to avoid any slip even when the cord suffers a pull force of 100N.