HP BladeSystem p-Class Enclosure Installation Guide March 2005 (Second Edition) Part Number 354556-002
10 HP BladeSystem p-Class Enclosure Installation Guide Each power enclosure has two or more power supply cords. A single rack or cabinet may contai
100 HP BladeSystem p-Class Enclosure Installation Guide NVRAM non-volatile memory OEM original equipment manufacturer ORCA Option ROM Configurati
Acronyms and abbreviations 101 RILOE Remote Insight Lights-Out Edition RILOE II Remote Insight Lights-Out Edition II RMA return material author
102 HP BladeSystem p-Class Enclosure Installation Guide USB universal serial bus
103 installing the cage nuts 20 Index J Japanese notice 88 A K additional information 95 Korean notices 89 authorized reseller 95 L B L
104 HP BladeSystem p-Class Enclosure Installation Guide technical support 95 telephone numbers 95 troubleshooting 77 W warnings 79 website
Planning the installation 11 CAUTION: Protect the equipment from AC power fluctuations and temporary interruptions with a regulating facility UPS
12 HP BladeSystem p-Class Enclosure Installation Guide Compaq branded 9000 Series racks provide proper server cooling from flow-through perforation
Planning the installation 13 It is important that the system be configured according to the guidelines in the HP BladeSystem p-Class System Overview
14 HP BladeSystem p-Class Enclosure Installation Guide In all other countries, you must install the equipment in accordance with any regional or na
15 Installing HP BladeSystem p-Class enclosures In this section Installation overview ...
16 HP BladeSystem p-Class Enclosure Installation Guide Measuring with the rack template NOTE: A rack template is not provided with the 1U power su
Installing HP BladeSystem p-Class enclosures 17 • "L" and "R" markings to identify left and right rack rails (from the front
18 HP BladeSystem p-Class Enclosure Installation Guide NOTE: The depth of an HP or a Compaq branded rack (29 in) is clearly indicated on the rack
Installing HP BladeSystem p-Class enclosures 19 b. Compress the spring-loaded rack rail toward the rear of the rack. c. Using the marks you mad
© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties
20 HP BladeSystem p-Class Enclosure Installation Guide Installing the cage nuts Installing HP BladeSystem p-Class enclosures into the rack NOTE:
Installing HP BladeSystem p-Class enclosures 21 Installing HP BladeSystem p-Class 1U Power Enclosures CAUTION: Always plan the rack installatio
22 HP BladeSystem p-Class Enclosure Installation Guide Item Description Configuration 1 Power supply bay 1 Bus A 2 Power supply bay 2 Bus A 3
Installing HP BladeSystem p-Class enclosures 23 Installing HP BladeSystem p-Class 3U Power Enclosures CAUTION: Always plan the rack installatio
24 HP BladeSystem p-Class Enclosure Installation Guide Item Description Configuration 1 Power supply bay 1 Bus A 2 Power supply bay 2 Bus A 3
Installing HP BladeSystem p-Class enclosures 25 Installing HP BladeSystem p-Class Server Blade Enclosures Installing interconnects Each server b
26 HP BladeSystem p-Class Enclosure Installation Guide Installing HP BladeSystem interconnect modules and RJ-45 patch panels NOTE: Always install
Installing HP BladeSystem p-Class enclosures 27 Installing HP BladeSystem interconnect modules and interconnect switches NOTE: Always install the
29 Cabling and powering up the system In this section System cabling overview...
3 Contents Planning the installation 7 Rack requirements...
30 HP BladeSystem p-Class Enclosure Installation Guide 2. Connect the network cables to the interconnects. Refer to the documentation that came w
Cabling and powering up the system 31 Identifying HP BladeSystem p-Class 1U Power Enclosure components Item Description Cable type 1 DC out
32 HP BladeSystem p-Class Enclosure Installation Guide Item Description Cable type 9 AC input power connector for bay 2 PDU power cord 10 AC in
Cabling and powering up the system 33 Item Description Cable type 6 AC input power connector for bus A AC power cord 7 DC output power connect
34 HP BladeSystem p-Class Enclosure Installation Guide Solution Power enclosures supported Server blade enclosures supported Maximum rack spa
Cabling and powering up the system 35 Installing a scalable bus bar kit NOTE: Use the location marks made when you measured the rack with the rac
36 HP BladeSystem p-Class Enclosure Installation Guide Installing a mini bus bar kit NOTE: Use the location marks made when you measured the rack
Cabling and powering up the system 37 WARNING: Be sure that all circuit breakers are locked in the off position before connecting any power com
38 HP BladeSystem p-Class Enclosure Installation Guide Installing the power connectors The power connectors are positioned to line up to adjacen
Cabling and powering up the system 39 WARNING: Be sure that all circuit breakers are locked in the off position before connecting any power com
4 HP BladeSystem p-Class Enclosure Installation Guide Management cabling guidelines ...
40 HP BladeSystem p-Class Enclosure Installation Guide On the server blade management module: • • • • • • The upper Management Link connects to th
Cabling and powering up the system 41 NOTE: Management modules are used only for information management (asset tracking, for example). Disconnect
42 HP BladeSystem p-Class Enclosure Installation Guide Connecting the HP BladeSystem p-Class 1U Management Link Cable When deploying the HP BladeSy
Cabling and powering up the system 43 Connecting to iLO NOTE: This section applies only to systems that are configured with an enhanced server bl
44 HP BladeSystem p-Class Enclosure Installation Guide Connecting the HP BladeSystem p-Class 1U DC power cable to the server blade enclosure Conn
Cabling and powering up the system 45 Removing the mini bus bar cover Connecting power cables to the mini bus bar WARNING: If using facility
46 HP BladeSystem p-Class Enclosure Installation Guide NOTE: If you are connecting two HP BladeSystem 3U Power enclosures to mini bus bars, refer
Cabling and powering up the system 47 Securing the mini bus bars Connecting power cables to a scalable bus bar Connect the DC power cables to th
48 HP BladeSystem p-Class Enclosure Installation Guide Removing the scalable bus bar covers WARNING: If using facility DC power, cables must be
Cabling and powering up the system 49 Replacing the scalable bus bar cover
Contents 5 Troubleshooting 77 Troubleshooting resources ...
50 HP BladeSystem p-Class Enclosure Installation Guide Securing the scalable bus bars Connecting the load-balancing signal cable When a power zon
Cabling and powering up the system 51 IMPORTANT: If the configuration does not include HP BladeSystem p-Class 3U Power Enclosures, no load-balanc
52 HP BladeSystem p-Class Enclosure Installation Guide WARNING: If using facility DC power, cables must be connected by a licensed electrician o
Cabling and powering up the system 53 • Scalable bus bar configuration example (on page 53) • Two mini bus bar configuration example (on page 54
54 HP BladeSystem p-Class Enclosure Installation Guide CAUTION: Always use blanks to fill empty spaces in enclosures. This arrangement ensures p
Cabling and powering up the system 55 CAUTION: Always use blanks to fill empty spaces in enclosures. This arrangement ensures proper airflow. U
56 HP BladeSystem p-Class Enclosure Installation Guide Full rack 42U solution with two pairs of mini bus bars Observe the following additional gui
Cabling and powering up the system 57 Item Description 1 Power zone 2 2 Zone 2 switches in the up (secondary) position 3 Power zone 1 4 Zo
58 HP BladeSystem p-Class Enclosure Installation Guide To configure the Dynamic Power Saver, remove the power enclosure management module. Use the
Cabling and powering up the system 59 Position Function 3 Reserved (off=default) Powering up the system WARNING: Be sure that all circuit br
60 HP BladeSystem p-Class Enclosure Installation Guide 7. Be sure that the server blade enclosure DC power LEDs are illuminated green. Refer to &q
Cabling and powering up the system 61 7. Be sure that the hot-plug power supply LEDs, power enclosure DC power LEDs, and bus bar power LEDs are i
62 HP BladeSystem p-Class Enclosure Installation Guide 4. Be sure that the server blade enclosure DC power LEDs are illuminated green. Refer to &q
63 LEDs, buttons, and switches In this section LEDs...
64 HP BladeSystem p-Class Enclosure Installation Guide Item LED Description Status 1 Bus B power Off = No power available Green = Power avai
LEDs, buttons, and switches 65 Item LED Description Status 2 Unit identification Blue = Identified Off = No active remote management 3 Power
66 HP BladeSystem p-Class Enclosure Installation Guide Use the following figure and table to identify LED locations and functions. Item LED De
LEDs, buttons, and switches 67 * All management link connector LEDs flash on all management modules when management modules are cabled improperly.
68 HP BladeSystem p-Class Enclosure Installation Guide Item LED Description Status 5 Fault status LED Red flashing = Fault process activity Of
LEDs, buttons, and switches 69 HP BladeSystem p-Class 3U Power Enclosure LEDs The power enclosure has two LEDs, one for each bus, to indicate DC p
7 Planning the installation In this section Rack requirements ...
70 HP BladeSystem p-Class Enclosure Installation Guide HP BladeSystem p-Class 1U Power Supply LEDs The power supply has two LEDs to indicate the p
LEDs, buttons, and switches 71 HP BladeSystem p-Class 3U Power Supply LEDs The power enclosure has two LEDs, one for each bus, to indicate DC powe
72 HP BladeSystem p-Class Enclosure Installation Guide Reset and UID buttons Each management module contains a reset button and UID button. Use th
LEDs, buttons, and switches 73 The server blade management modules and power management modules have a two-position switch that identifies the use
74 HP BladeSystem p-Class Enclosure Installation Guide IMPORTANT: All power configuration switches in the same zone must be set to the same positi
LEDs, buttons, and switches 75 Item 1 Power zone 2 2 Zone 2 switches in the up (secondary) position 3 Power zone 1 4 Zone 1 switches in t
77 Troubleshooting In this section Troubleshooting resources...
78 HP BladeSystem p-Class Enclosure Installation Guide Important safety information Before servicing this product, read the Important Safety Inf
Troubleshooting 79 21.55 - 36.33 kg 47.5 - 80.1 lbs. This symbol indicates that the component exceeds the recommended weight for one individual t
8 HP BladeSystem p-Class Enclosure Installation Guide Warnings, cautions, and importants WARNING: To reduce the risk of personal injury or damag
80 HP BladeSystem p-Class Enclosure Installation Guide The leveling feet are extended to the floor. • • • • • The full weight of the rack rests on
Troubleshooting 81 Observe local occupation health and safety requirements and guidelines for manual handling. • • • • Obtain adequate assistance to
83 Regulatory compliance notices In this section Regulatory compliance identification numbers...
84 HP BladeSystem p-Class Enclosure Installation Guide Federal Communications Commission notice Part 15 of the Federal Communications Commission (F
Regulatory compliance notices 85 Class B equipment This equipment has been tested and found to comply with the limits for a Class B digital device,
86 HP BladeSystem p-Class Enclosure Installation Guide • • Hewlett-Packard Company P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000 1-2
Regulatory compliance notices 87 European Union regulatory notice This product complies with the following EU Directives: • • Low Voltage Directive
88 HP BladeSystem p-Class Enclosure Installation Guide Japanese notice Power cord statement for Japan BSMI notice
Regulatory compliance notices 89 Korean notice A&B Class A equipment Class B equipment Laser compliance This product may be provided with a
Planning the installation 9 WARNING: The power enclosure and the server blade enclosure are very heavy. To reduce the risk of personal injury or
90 HP BladeSystem p-Class Enclosure Installation Guide Do not try to open the module enclosure. There are no user-serviceable components inside. •
Regulatory compliance notices 91 Taiwan battery recycling notice The Taiwan EPA requires dry battery manufacturing or importing firms in accordance
93 Electrostatic discharge In this section Preventing electrostatic discharge ...
94 HP BladeSystem p-Class Enclosure Installation Guide Grounding methods to prevent electrostatic discharge Several methods are used for grounding.
95 Technical support In this section Before you contact HP...
96 HP BladeSystem p-Class Enclosure Installation Guide – Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days a
97 Acronyms and abbreviations ACU Array Configuration Utility BBWC battery-backed write cache BIOS Basic Input/Output System BOOTP Bootstrap P
98 HP BladeSystem p-Class Enclosure Installation Guide DIMM dual inline memory module DMA direct memory access ECC error checking and correcting
Acronyms and abbreviations 99 iLO Integrated Lights-Out ISEE Instant Support Enterprise Edition LAN local-area network LED light-emitting diode
Kommentare zu diesen Handbüchern